Fluxio
309.4 KLiquid cooling · Liquid
Fluxio: liquid and direct-to-chip cooling optimization.
Dense AI racks need liquid cooling, and most tools have no idea what happens inside the loop. Fluxio models coolant flow, pressure and cold-plate temperatures, flags leaks early and tunes pumps and supply temperature.
Example values.
306.8 KCapabilities
What it does.
01
Loop model
Coolant flow, pressure and temperature through CDUs, manifolds and cold plates.
02
Cold-plate forecasts
Per-rack and per-plate temperature headroom under the coming load.
03
Leak and flow anomalies
Pressure and flow signatures that suggest a leak or blockage, flagged early.
04
Pump and setpoint tuning
The warmest safe supply temperature and the lowest pump energy.
05
Air and liquid together
What moving a cluster to liquid removes from the air side, and what it adds to the loop.
06
Closed-loop control
Through Cryon, with the same envelope and approvals. Planned.
304.2 KSupply temperature
Warmer water, same chips.
Raising CDU supply temperature saves chiller energy until the cold plates run out of headroom. Move the sliders.
Planning arithmetic for one 120 kW direct-to-chip rack: cold plate = supply + 14 °C + 1,440 ÷ flow, limit 85 °C; chiller-free hours from a mild-climate weather year; pump power rises with the cube of flow. Illustrative, not a Fluxio result.
68 °C
hottest cold plate
Illustrative
17 °C
headroom to the 85 °C limit
Illustrative
4,720
chiller-free hours per year
Illustrative
100
pump energy index (80 L/min = 100)
Illustrative
301.6 KHow it works
One cycle, start to finish.
01Each minute
Read
CDU, flow, pressure and temperature points.
02Seconds
Model
Loop and cold-plate state on the twin.
03Continuous
Flag
Anomalies and shrinking headroom.
04Hourly
Tune
Proposed supply and pump setpoints.
05Your pace
Approve
Operators apply them through Cryon.
299.0 KSpecification
The details.
| Item | Detail |
|---|---|
| Inputs | CDU telemetry, flow meters, pressure sensors, rack and GPU power, the Thermyx twin |
| Model | Reduced-order loop models with ML corrections; full coupled fluid dynamics later |
| Outputs | Cold-plate headroom, leak and flow flags, supply and pump proposals |
| Cooling types | Direct-to-chip, rear-door heat exchangers; immersion later |
| Status | In development |
296.4 KIn the loop
Where it sits.
Realized temperatures and energy flow back and recalibrate the twin
Fluxio is the liquid layer of the same twin, so air-side and liquid-side decisions are made together.
293.8 KQuestions
Straight answers.
Do you support immersion cooling?
Not at first. Direct-to-chip and rear-door heat exchangers come first.
Can Fluxio raise GPU clocks?
It reports thermal headroom per rack. What you do with it is your decision.
Do we need new sensors on the loop?
Most CDUs already report flow, pressure and temperatures. We will tell you if a gap matters.
291.2 KNext step
Give us one hall. We will show you where the heat goes.
Send a floor plan, a month of BMS and DCIM trends and the rules your cooling runs on today. We build a Thermyx twin of that hall, replay the month and show you the hotspots it would have predicted and the cooling energy it would have saved. Advisory only: nothing touches your controls.