Fluxio

309.4 KLiquid cooling · Liquid

Fluxio: liquid and direct-to-chip cooling optimization.

Dense AI racks need liquid cooling, and most tools have no idea what happens inside the loop. Fluxio models coolant flow, pressure and cold-plate temperatures, flags leaks early and tunes pumps and supply temperature.

CDU 3Supply36 °C
CDU 3Flow80 L/min per rack
CDU 3Hottest cold plate68 °C
CDU 3Leak riskLow

Example values.

306.8 KCapabilities

What it does.

01

Loop model

Coolant flow, pressure and temperature through CDUs, manifolds and cold plates.

02

Cold-plate forecasts

Per-rack and per-plate temperature headroom under the coming load.

03

Leak and flow anomalies

Pressure and flow signatures that suggest a leak or blockage, flagged early.

04

Pump and setpoint tuning

The warmest safe supply temperature and the lowest pump energy.

05

Air and liquid together

What moving a cluster to liquid removes from the air side, and what it adds to the loop.

06

Closed-loop control

Through Cryon, with the same envelope and approvals. Planned.

304.2 KSupply temperature

Warmer water, same chips.

Raising CDU supply temperature saves chiller energy until the cold plates run out of headroom. Move the sliders.

Planning arithmetic for one 120 kW direct-to-chip rack: cold plate = supply + 14 °C + 1,440 ÷ flow, limit 85 °C; chiller-free hours from a mild-climate weather year; pump power rises with the cube of flow. Illustrative, not a Fluxio result.

68 °C

hottest cold plate

Illustrative

17 °C

headroom to the 85 °C limit

Illustrative

4,720

chiller-free hours per year

Illustrative

100

pump energy index (80 L/min = 100)

Illustrative

301.6 KHow it works

One cycle, start to finish.

  1. 01Each minute

    Read

    CDU, flow, pressure and temperature points.

  2. 02Seconds

    Model

    Loop and cold-plate state on the twin.

  3. 03Continuous

    Flag

    Anomalies and shrinking headroom.

  4. 04Hourly

    Tune

    Proposed supply and pump setpoints.

  5. 05Your pace

    Approve

    Operators apply them through Cryon.

299.0 KSpecification

The details.

Fluxio specification (draft)
ItemDetail
InputsCDU telemetry, flow meters, pressure sensors, rack and GPU power, the Thermyx twin
ModelReduced-order loop models with ML corrections; full coupled fluid dynamics later
OutputsCold-plate headroom, leak and flow flags, supply and pump proposals
Cooling typesDirect-to-chip, rear-door heat exchangers; immersion later
StatusIn development

296.4 KIn the loop

Where it sits.

Thermyxlive twin state

Realized temperatures and energy flow back and recalibrate the twin

Fluxio is the liquid layer of the same twin, so air-side and liquid-side decisions are made together.

293.8 KQuestions

Straight answers.

Do you support immersion cooling?

Not at first. Direct-to-chip and rear-door heat exchangers come first.

Can Fluxio raise GPU clocks?

It reports thermal headroom per rack. What you do with it is your decision.

Do we need new sensors on the loop?

Most CDUs already report flow, pressure and temperatures. We will tell you if a gap matters.

291.2 KNext step

Give us one hall. We will show you where the heat goes.

Send a floor plan, a month of BMS and DCIM trends and the rules your cooling runs on today. We build a Thermyx twin of that hall, replay the month and show you the hotspots it would have predicted and the cooling energy it would have saved. Advisory only: nothing touches your controls.