309.4 KPlatform

One live model of the hall. Every decision checked against it.

Kelvalis is one platform with one twin underneath. Telemetry comes in, the twin predicts, the optimizer proposes, people approve, and what actually happened goes back into the twin.

TwinPrediction horizon15 min
TwinCalibration error< 0.5 °C
ControlEnvelope checksevery action
EdgeLoopon-site

Design targets for the first pilot halls.

306.8 KArchitecture

Six layers.

Kelvalis platform layers
LayerWhat it doesBuilt on
1 · IngestBMS, DCIM, meter and sensor telemetry, plus the floor plan, cleaned and aligned in time.RAPIDS, BACnet, Modbus, OPC UA
2 · Thermal twinA physics-ML model of airflow, temperature and power, calibrated continuously.Modulus, CUDA, Omniverse
3 · PredictionInlet temperature forecasts per rack and anomaly flags.Physics-ML surrogates, time-series models
4 · OptimizerCooling and power setpoints, rack placement and schedules under hard constraints.Reinforcement learning, cuOpt
5 · Console and copilotThe 3D hall, alerts, approvals and plain-language answers.Omniverse, NeMo, Guardrails
6 · Edge and feedbackThe on-site control loop, and realized outcomes back into the twin.Jetson, TensorRT

304.2 KFlywheel

It gets better with every hall.

Data

More halls

Each twin adds geometry, telemetry and control outcomes to one thermal dataset.

Models

Better models

Shared physics-ML and RL models learn from every hall and calibrate faster on the next.

Outcomes

Bigger savings

Sharper predictions mean tighter setpoints, so each hall saves more energy and frees more capacity.

301.6 KProducts

Five products on one twin.

Thermyxlive twin state

Realized temperatures and energy flow back and recalibrate the twin

299.0 KDeployment

Run it where your facility data lives.

Default for control

On-site

The full platform on your servers, with the control loop on Jetson nodes in the hall. Nothing leaves the site.

Hybrid

Private cloud

Twin training and what-if runs in your cloud account; the control loop stays on-site.

Pilots

Kelvalis cloud

For read-only pilots and design studies, with a VPN or a one-way data diode from the site.

296.4 KCopilot

Ask the hall a question.

The copilot answers from the twin and the action log, not from guesswork.

  • Why did Cryon change that setpoint, and what did it predict?
  • What happens if this CRAH trips at the afternoon peak?
  • Which rows can take the next 20 GPU racks?
  • Draft this month’s PUE and energy report.
Copilot · hall 2Example

OperatorWhy did you raise supply air in hall 2 at 03:10?

Kelvalis copilotNight load dropped 14 %. The twin showed every inlet at least 3.1 °C below 27 °C, so Cryon proposed 18.0 → 19.5 °C on L1–L4. You approved it at 03:12. Predicted saving: 38 kW of cooling power until 07:00. Hottest inlet since then: 24.8 °C on B-07.

OperatorWhat happens if R2 trips at the afternoon peak?

Kelvalis copilotRunning SC-03 on today’s forecast: rows B and C pass 27 °C after 9 minutes with current setpoints, or stay below 26.4 °C if Cryon pre-stages R4. I have drafted that pre-stage as action A-124 for your approval.

293.8 KSecurity

Built for critical facilities.

Network

Isolated control

The control loop runs on-site with no inbound internet path.

Access

Least privilege

Read-only by default; write access only to named setpoints.

Audit

Full audit

Every prediction, proposal, approval and rollback logged.

Data

Your data

Telemetry stays yours. Cross-site learning only with written opt-in.

291.2 KNext step

Give us one hall. We will show you where the heat goes.

Send a floor plan, a month of BMS and DCIM trends and the rules your cooling runs on today. We build a Thermyx twin of that hall, replay the month and show you the hotspots it would have predicted and the cooling energy it would have saved. Advisory only: nothing touches your controls.