309.4 KPlatform
One live model of the hall. Every decision checked against it.
Kelvalis is one platform with one twin underneath. Telemetry comes in, the twin predicts, the optimizer proposes, people approve, and what actually happened goes back into the twin.
Design targets for the first pilot halls.
306.8 KArchitecture
Six layers.
| Layer | What it does | Built on |
|---|---|---|
| 1 · Ingest | BMS, DCIM, meter and sensor telemetry, plus the floor plan, cleaned and aligned in time. | RAPIDS, BACnet, Modbus, OPC UA |
| 2 · Thermal twin | A physics-ML model of airflow, temperature and power, calibrated continuously. | Modulus, CUDA, Omniverse |
| 3 · Prediction | Inlet temperature forecasts per rack and anomaly flags. | Physics-ML surrogates, time-series models |
| 4 · Optimizer | Cooling and power setpoints, rack placement and schedules under hard constraints. | Reinforcement learning, cuOpt |
| 5 · Console and copilot | The 3D hall, alerts, approvals and plain-language answers. | Omniverse, NeMo, Guardrails |
| 6 · Edge and feedback | The on-site control loop, and realized outcomes back into the twin. | Jetson, TensorRT |
304.2 KFlywheel
It gets better with every hall.
Data
More halls
Each twin adds geometry, telemetry and control outcomes to one thermal dataset.
Models
Better models
Shared physics-ML and RL models learn from every hall and calibrate faster on the next.
Outcomes
Bigger savings
Sharper predictions mean tighter setpoints, so each hall saves more energy and frees more capacity.
301.6 KProducts
Five products on one twin.
Realized temperatures and energy flow back and recalibrate the twin
299.0 KDeployment
Run it where your facility data lives.
Default for control
On-site
The full platform on your servers, with the control loop on Jetson nodes in the hall. Nothing leaves the site.
Hybrid
Private cloud
Twin training and what-if runs in your cloud account; the control loop stays on-site.
Pilots
Kelvalis cloud
For read-only pilots and design studies, with a VPN or a one-way data diode from the site.
296.4 KCopilot
Ask the hall a question.
The copilot answers from the twin and the action log, not from guesswork.
- Why did Cryon change that setpoint, and what did it predict?
- What happens if this CRAH trips at the afternoon peak?
- Which rows can take the next 20 GPU racks?
- Draft this month’s PUE and energy report.
OperatorWhy did you raise supply air in hall 2 at 03:10?
Kelvalis copilotNight load dropped 14 %. The twin showed every inlet at least 3.1 °C below 27 °C, so Cryon proposed 18.0 → 19.5 °C on L1–L4. You approved it at 03:12. Predicted saving: 38 kW of cooling power until 07:00. Hottest inlet since then: 24.8 °C on B-07.
OperatorWhat happens if R2 trips at the afternoon peak?
Kelvalis copilotRunning SC-03 on today’s forecast: rows B and C pass 27 °C after 9 minutes with current setpoints, or stay below 26.4 °C if Cryon pre-stages R4. I have drafted that pre-stage as action A-124 for your approval.
Network
Isolated control
The control loop runs on-site with no inbound internet path.
Access
Least privilege
Read-only by default; write access only to named setpoints.
Audit
Full audit
Every prediction, proposal, approval and rollback logged.
Data
Your data
Telemetry stays yours. Cross-site learning only with written opt-in.
291.2 KNext step
Give us one hall. We will show you where the heat goes.
Send a floor plan, a month of BMS and DCIM trends and the rules your cooling runs on today. We build a Thermyx twin of that hall, replay the month and show you the hotspots it would have predicted and the cooling energy it would have saved. Advisory only: nothing touches your controls.